87
Event number can be mapped as a Sensor port and camera number.
DI Open State :
This means that sensor is triggered and become open status from Normal close status.
Select this when you use NC(Normal Close) type sensor.
DI Close State :
This means that sensor is triggered and become close status from Normal open. Select
this when you use NO (Normal Open) type sensor.
Motion Detection :
By selecting this option, motion detection based event can be configured.
Camera Connected and Disconnected:
Camera status change by lost of camera signal can be recognized as an event
Boot Finished :
Boot finish means Server reboot. Thus, when the server is rebooted, it can be recognized
as an event.
Serial input :
FlexWATCH
TM
server can carry serial data along with video. When serial data from
external serial device is activated, this can be recognized as a event.
Sensor state means when the sensor status is Open or closed. If you use NC( Normal
Close) type sensor and activate any action when sensor is open, you need to
select [Open State] and vice versa when you use NO (Normal Open) type of
sensor.
) Please check out sensor type connected to FlexWATCH
TM
server