19-16 Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
ip ospf dead-interval
Command Mode Interface Configuration.
Description Sets the dead interval time for neighbors to declare this router down. Dead
interval is the time that hello packets are not seen. This value must be the
same for all routers attached to a common network. The value range is 1-
65535 seconds. The default setting is 40 seconds.
To return to the default time, use the no form of this command.
Syntax
Sample Output The following command sets the dead interval time to 60 seconds.
(config-if:intf3)# ip ospf dead-interval 60
Systems P550R, P580, P880, and P882.
To Configure: ip ospf dead-interval <seconds>
To Restore Default: [no] ip ospf dead-interval
Table 19-11. Parameters, Keywords, Arguments
Name Definition
<seconds> Time in seconds of how long hello packets must be unseen
before the neighbor declares the router down. This value must be
the same for all routers attached to a common network.
The value range is 1-65535 seconds. The default setting is 40
seconds.