of 764
 
Chapter 19
19-22 Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
ip ospf poll interval
Command Mode Interface Configuration.
Description Specifies the poll interval time. The valid range is 1 to 3600 seconds. The
default setting is 120 seconds. The no command restores the default setting.
Syntax
Sample Output
The following command sets the poll interval time on interface 123 to 2000
seconds.
(config-if:123)# ip ospf poll-interval 2000
Systems P550R, P580, P880, and P882.
To Configure: ip ospf poll-interval <seconds>
To Restore Default: [no] ip ospf poll-interval
Table 19-15. Parameters, Keywords, Arguments
Name Definition
<seconds> Time in seconds between retransmissions. It must be greater
than the expected round-trip delay between any two routers on
the attached network. The range is 1 to 3600 seconds.